SA210 A1 Boiler Tubes Wall Thickness Tolerance
Seamless, Cold-Finished Tubes | ||
Outside Diameter In. (mm) |
Wall thickness Tolerance % | |
Over (+) | Under (-) | |
1 ½ (38.1) and under | 20 | 0 |
Over 1½ (38.1) | 22 | 0 |
Cold-Finished Seamless Tubes | ||
Outside Diameter In. (mm) |
Permissible Variations In. (mm) | |
Over (+) | Under (-) | |
Under 1 (25.4) | 0.004 (0.1) | 0.004 (0.1) |
1 to 1 ½ (25.4 to 38.1), Incl | 0.006 (0.15) | 0.006 (0.15) |
Over 11⁄2 to 2 (38.1 to 50.8), Excl | 0.008 (0.2) | 0.008 (0.2) |
2 to 21⁄2 (50.8 to 63.5), Excl | 0.010 (0.25) | 0.010 (0.25) |
21⁄2 to 3 (63.5 to 76.2), Excl | 0.012 (0.3) | 0.012 (0.3) |
Cold-Finished Seamless Tubes | |||
Outside Diameter, In.(mm) |
Cut Length,in.(mm) | ||
Over (+) | Under (-) | ||
All Sizes | 3⁄16 [5] | 0 [0] | |
Under 2 (50.8) | 1⁄8 [3] | 0 [0] | |
2 (50.8) and over | 3⁄16 [5] | 0 [0] | |
Under 2 (50.8) | 1⁄8 [3] | 0 [0] | |
2 (50.8) and over | 3⁄16 [5] | 0 [0] | |
These permissible variations in length apply to tubes before bending. They apply to cut lengths up to and including 24 ft [7.3 m]. For lengths greater than 24 ft [7.3 m], the above over-tolerances shall be increased by 1⁄8 in. [3 mm] for each 10 ft [3 m] or fraction thereof over 24 ft or 1⁄2 in. [13 mm], whichever is the lesser |
SA210 A1 Chemical Compositions
Chemical Components (%) | ||||||||
Grade | C | Si | Mn | P | S | Mo | Cr | V |
A-1 | ≤0.27 | ≥0.10 | ≤0.93 | ≤0.035 | ≤0.035 | / | / | / |
SA210 A1 Mechanical Tests Required
Mechanical Properties | ||||
Grade | Tensile Strength (Mpa) |
Yield Strength (Mpa) |
Elongation (%) |
Hardness (HRB) |